Features
- Unique Reversed Impeller design, ensuring Mechanical Seal is never subjected to high pressure from the pump
- High shut off head of 33 metres
- Double mechanical seal in oil bath, operating at static head pressure only ensures reliable trouble-free operation
- Unique cable sealing protects from water entering the motor
- Heavy-duty upper and lower ball bearings ensure smooth operation and support axial load/thrust
- Built-in float switch for automatic liquid level operation
Caution
Do not operate AD32-750 pump below 12m head as it may cause cavitation, vibrations etc… which may damage the pump. Such damage is not covered under warranty. For duty conditions under 12m head you may use W-400 submersible pump.
Technical Data
Part Number | AD32-750 | Weight (kg) | 17 |
Motor (kW/HP) | 0.75 / 1.0 | Outlet (mm) | 25 BSP |
Power (Volts) | 230 - 240 | Full Load Current (A) | 5.24 amps |
Pump Dimensions (mm) | 360(H) x 250(W) | Min Sump Dimension | 700x700x700mm |
Phase | Single | Cable Length | 10M |
Suitable for pumping clear water, treated filtered effluent only NOT SUITABLE for sewage & waste water with solids
Min Sump Height (mm)
700
Min Sump Width (mm)
700
Min Sump Length (mm)
700
Weight (Kg)
17
Pump Height (mm)
360
Pump Width (mm)
250
Outlet (mm)
25 BSP
Power Supply (Volts/Phase)
230 - 240 /1
Motor (kW/ HP)
0.75 / 1.0
Full Load Current (Amps)
5.24
Caution
Do not operate AD32-750pump below 12m head as it may cause cavitation, vibrations etc, which may damage the pump. Such damage is not covered under warranty. For duty conditions under 12m head you may use W-400 submersible pump.
INSTALLATION INSTRUCTIONS